Battery hmanga chakna dahkhawmna systempower siamchhuah, transmission leh consumption zawng zawngah te chuan hman a ni. An response time tawi, fast adjustment speed leh control precision sang tak an neih avangin application area zawng zawngah expansion nasa tak leh function emaw performance lama hmasawnna nasa tak an thlen a ni.

Thermal Power Unit-a AGC chungchanga thu bulpui ber berte
Power system-a frequency leh active power atana automatic control system chu Automatic Generator Control (AGC) an ti a. A tlangpuiin distributed control system (DCS) kaltlangin power grid dispatch center-in direct-a unit siamna atana target load command automatic-a tihpun emaw tihhniam emaw a kawk a ni. Unit siam chhuahna hna bulpui ber a ni.
Electrical energy quality sang- siam chhuah tumna hnuaiah hian AGC (Automatic Generation Control) hian power supply leh demand-a real-time balance a tihlawhtling a, minute tlemte atanga minute sawm chhungin load inthlak danglamna chu a chhang let a, chuvangin secondary frequency regulation-ah a tel a ni. A hna bulpui berte chu grid frequency chu allowable error range chhunga vawn reng a ni a, chu chu frequency error-free adjustment; interconnected grid-a net exchange power control-in a man ruahman angin a thawk thei ang; interconnected grid-a electrical energy inthlak danglam chu ruahman sa chhunga control; leh remote regulation-a tel power plant (unit)-te chu optimal economic allocation principle anga kalpui turin inremna siam a, chutiang chuan grid hlawkna tam ber a awm theih nan, grid himna tihkhawtlai, grid frequency, leh external net exchange power plan te zawm theihna tur thupui hnuaiah, chutiang chuan tertiary frequency regulation-ah tel a ni.

Power system him leh nghet taka kalpui a nih theih nan AGC (Automatic Generation Control) hnathawhnaah tel generating unit-te capacity leh adjustable capacity atan target requirement a awm a ni. China power system-ah chuan AGC-a tel unit-te rated capacity hian a tlangpuiin system-a installed capacity zawng zawng aṭanga 50% aia tam an luah a ngai a, AGC-a tel unit-te adjustable capacity hian system peak load 15% aia tam a luah a ngai bawk. A bik takin, AGC-a tel thermal power unit-te tan chuan rated power chu P a nih chuan power regulation range chu a tlangpuiin 50%P atanga 100%P a ni a; minute khata power change rate sang ber chu 3%P a ni a; load regulation chhanna hun chu second 30 aia tlem lo a ni tur a ni; leh dynamic regulation error atan chuan 300MW thermal power unit entirnan la ila, regulation error chu 3MW aia tlem a ni a, maximum error chu 5MW aia tlem a ni bawk.

AGC system hi a lem a kan hmuh ang hian power grid dispatch center-a AGC controller, real-time transmission channel, remote control unit (RTU), leh unit DCS te a ni ber. Power grid dispatch center hian grid load, unit operating status, leh grid frequency chungchanga real-time data hmanga siam hian unit-te hnenah remote-in load a thawn chhuak a, AGC command a siam chhuak thin.
Heng command te hi power plant-a RTU-ah remote transmission channel hmangin an thawn chhuak a, chu chu carrier communication hmangin a ni. Chumi hnuah RTU chuan AGC command te chu 4-20mA current signal angin unit DCS ah a thawn chhuak leh thin. DCS hian unit power output tak tak chu load limit leh load change rate setpoints hmangin a siamrem a, AGC command te chu a track a ni. Chutih rual chuan unit-a real-time status, power output tak tak, AGC activation status, load leh change rate limit te chu transmitter-te chuan 4-20mA signal-ah an chantir a, RTU-ah an thawn chhuak bawk. Chumi hnuah RTU chuan unit-a real-time status chu telemetry data-ah a chantir a, chu chu high-frequency carrier communication hmangin remote transmission channel hmangin power grid dispatch center-ah a thawn chhuak a ni. Chuvangin AGC hi power siamna atana remote closed-loop control system a ni a, computer hmanga Supervisory Control and Data Acquisition (SCADA) system, generator set coordination control system leh information transmission system rintlak tak hmanga siam a ni.
Thermal power unit-a AGC regulation leh typical response process chu figure-ah hian tarlan a ni:

Power plant-te'n power grid-a paid ancillary service an pek angin, AGC (Automatic Generation Control) hi grid-connected generation ancillary service management leh grid-connected operation management ("the two rules" tia sawi) atana hman tur dan chipchiar tak tak, a inmil tur hmangin regional power grid hrang hrangin an thunun a ni. Heng dante hian AGC telin paid ancillary services te performance index chhiar leh assessment dan tur chungchangah dan chipchiar tak a siam a ni. North China regional power grid-a power plant-te tana "rules pahnih" (2019 revised version) chu entirnan la ila, AGC service pe thin generator unit-te tana assessment indicator-ah hian profitability index K a tel a niAleh regulation performance index K te a nip, chutah chuan Kptih hi a hnuaia formula-ah hian tarlan a ni:
Kp=K1×K2×K3
Formula-ah chuan:
K1
regulation rate, 2-(unit-a regulation rate tak tak / unit-a standard regulation rate) a ni.
K2
regulation dikna, 2-(regulation deviation / phalna regulation deviation)
K3
chhanna hun, 2-(unit output chhanna hun / unit-a chhanna hun pangngai)
AGC service contribution ni-a compensation fee chu hetiang hian chhut a ni:
A
D-AGC adjustment depth (MW), cycle khat chhunga AGC command-te cumulative absolute value.
B
Kpd-Performance index, ni khat chhunga AGC adjustment process chhunga adjustability index awm zat cumulative value.
C